Product Category

Multifunctional vacuum generator

-The energy-saving vacuum generator reduces airconsumption by 90% (compared to a one-stagegenerator) and increases air consumption by 30%.

-Miniaturization, lightweight, integrated design, withsignal feedback, backflush release, impurity filtration.

-The filter can be visually inspected for cleanliness foreasy cleaning.

-The installation method is diversified.

Product Description

Performance parameter

Model

 

Gassupply pressure

bar

Maximumvacuum

-kPa

Maximumvacuum flowL/min Airconsumption

L/min

 

Noise level

dB(A)

 

Single(g) 
Without switch With switch

 

VK-P 3.7  90 40  32 65~70 88.5 102.5
VK-M 5.0 93 41 32 65~70 88.5 102.5

 

Vacuum flow rate (L/min) with different vacuum (-kPa)
Model  Gassupply pressure bar  AirconsumptionL/min

 

0 10 20 30 40 50 60 70 80 90 Maximumvacuum flowL/min 
VK-P

 

2.0 20 30.0 19.5 12.3 8.5 4.6 60
3.0 29 36.0 29.0  

19.8

12.5 10.3 8.5 6.1 3.1 1.1 89
3.7 32 40.0 35.0 25.2 17.7 10.9 8.0 5.6 4.2 1.5 1.0 90
VK-M 4.5 27 40.0 34.0 24.5 15.0 11.5 9.5 6.8 4.5 2.5 92
5.0 29 41.0 36.0 26.0 13.7 11.0 9.3 6.6 4.6 2.7 2.0 93
6.0 32 39.0 38.0 30.0 22.4 15.0 8.3 6.2 4.6 1.9 94

 

Vacuum pumping time (s/L) with diferent vacuum (-kPa)
Model  Gassupply pressure bar  AirconsumptionL/min

 

10 20 30 40 50 60 70 80 Maximumvacuum flowL/min 
VK-P

 

2.0 20 0.11 0.48 1.07 2.02 4.78 60
3.0 29 0.08 0.25 0.67 1.25 1.93 2.9 4.44 7.7 89
3.7 32 0.05 0.3 0.71 1.26 1.95 2.97 4.49 6.95 90
VK-M 4.5 27 0.2 0.56 1.1 1.7 2.56 3.95 6.08 92
5.0 29 0.02 0.14 0.47 0.96 1.56 2.5 3.87 6 93
6.0 32 0.13 0.4 0.8 1.5 2.47 3.85 6.25 94

 

Performance parameter

Model

KP92V-010

KP92V-030

Rated pressure range

-100~100kPa

Set pressure range

-105-105kPa

Pressure resistance

500kPa

General gas

Air, non-corrosive, non-flammable

Voltage

 24V DC soil 10%,pulse (P-P) 10% or less

Current consumption

≦40mA (when no load)

 Switch output

Output mode

2NPN or 2PNP open collector output NPN or PNP open collector output

Maximum load current

125mA

Maximum supply voltage

30VDC ( NPN },24VDC ( NPN )

24VDC

Internal pressure drop

≦1.5V

Response time

≦2.5ms (preventive malfunction: 2.5ms, 20ms, 100ms, 500ms, 1000ms and 1999ms optional)

2.5ms (preventive malfunction: 2.0ms, 100ms, 250ms, 500ms, 1000ms and 1500ms optional)
Outputshortcircuitprotection

Have

 OUT switch: Yes; V-Sol/D-Sol: None

Repeatability

±0.2%F.S±1 digit

Display method

3% digit LED 7-segment display {red) (sampling rate: 5 times/sec)
Display accuracy

±20/0F.S±1 digit

Action indicator light

OUT1: Green / OUT2: Red

Environmentally resistant

Protective structure

IP40

Operating temperature range

Action: 0~50°C Action: 0-50°C

Withstand voltage

1000VAC 1 minute (between lead and case)

Insulation resistance

50M Ω or more (500VDC) (between lead and case)

Temperature characteristics ±2%F.S. (within 0~50° C temperature range)
Wire

Oil resistant PVC wire (0.15mm2)

Ask For A Quick Quote